From sacadmin Wed Jul 20 17:10:10 2005
Received: from thunk.east.sun.com (thunk.East.Sun.COM [129.148.174.66])
	by sac.sfbay.sun.com (8.12.9+Sun/8.12.9) with ESMTP id j6L0A9Eu007514
	for <PSARC@sac.sfbay.sun.com>; Wed, 20 Jul 2005 17:10:10 -0700 (PDT)
Received: from 127.0.0.1 (localhost [127.0.0.1])
	by thunk.east.sun.com (8.13.4+Sun/8.13.4) with ESMTP id j6L0A8ND101310;
	Wed, 20 Jul 2005 20:10:09 -0400 (EDT)
Subject: Re: SVM default interlace and resync buffer increase
	[PSARC/2005/427 Timeout:  07/27/2005]
From: Bill Sommerfeld <sommerfeld@sun.com>
To: Brian Utterback <blu@sr1-unsh01-03.east.sun.com>
Cc: PSARC@sac.sfbay.sun.com, Truong.Q.Nguyen@sun.com
In-Reply-To: <200507201915.j6KJFmZg033453@sr1-unsh01-03.East.Sun.COM>
References: <200507201915.j6KJFmZg033453@sr1-unsh01-03.East.Sun.COM>
Content-Type: text/plain
Message-Id: <1121904608.100966.145.camel@thunk>
Mime-Version: 1.0
X-Mailer: Ximian Evolution 1.4.6.316 
Date: Wed, 20 Jul 2005 20:10:08 -0400
Content-Transfer-Encoding: 7bit
Status: RO
Content-Length: 1228

On Wed, 2005-07-20 at 15:15, Brian Utterback wrote:
> Summary:  This proposal requests a change to the default interlace value for SVM
> 	stripes and RAID5 metadevices and the mirror resync buffer size.  The
> 	new default interlace and resync buffer value of 512KB would result in
> 	15 to 50+ percent increase in throughput for I/O greater 16KB and half
> 	the resynchronization time for mirror initialization and component
> 	failure/recovery.

On a v40z I set up recently, I noticed substantially *reduced* svm
mirror initialization performance when I set the resynch buffer size to
the maximum value, compared with the small default in nevada as of when
I installed it.
(the documentation seemed to imply performance could only increase with
a larger buffer size....)

I haven't had time to dig into this and the box is now in production.

how much measurement of speed vs. resynch buffer size have you done
across different hardware?

maybe this is overengineering but can we somehow make this self-tuning? 
mirror resynchs typically take at least a few minutes; seems like you
could do a slow-start-like trick (spend a couple seconds copying at each
power-of-two-size and then back off if it slows down appreciably?)





From sacadmin Thu Jul 21 13:59:17 2005
Received: from phys-giza-1 (phys-giza-1.Central.Sun.COM [129.147.4.102])
	by sac.sfbay.sun.com (8.12.9+Sun/8.12.9) with ESMTP id j6LKxGEu021123
	for <PSARC@sac.sfbay.sun.com>; Thu, 21 Jul 2005 13:59:16 -0700 (PDT)
Received: from conversion-daemon.giza-mail1.Central.Sun.COM by
 giza-mail1.Central.Sun.COM
 (iPlanet Messaging Server 5.2 HotFix 1.24 (built Dec 19 2003))
 id <0IJZ00101WLU0B@giza-mail1.Central.Sun.COM>
 (original mail from Truong.Q.Nguyen@Sun.COM) for PSARC@sac.sfbay.sun.com; Thu,
 21 Jul 2005 14:59:16 -0600 (MDT)
Received: from [172.20.25.177] (caolila.Central.Sun.COM [172.20.25.177])
 by giza-mail1.Central.Sun.COM
 (iPlanet Messaging Server 5.2 HotFix 1.24 (built Dec 19 2003))
 with ESMTP id <0IJZ009A8WYOI1@giza-mail1.Central.Sun.COM>; Thu,
 21 Jul 2005 14:59:12 -0600 (MDT)
Date: Thu, 21 Jul 2005 14:47:04 -0600
From: Tony Nguyen <Truong.Q.Nguyen@Sun.COM>
Subject: Re: SVM default interlace and resync buffer increase	[PSARC/2005/427
 Timeout:  07/27/2005]
In-reply-to: <1121904608.100966.145.camel@thunk>
To: Bill Sommerfeld <sommerfeld@sun.com>
Cc: Brian Utterback <blu@sr1-unsh01-03.east.sun.com>, PSARC@sac.sfbay.sun.com,
   Sanjay Nadkarni <Sanjay.Nadkarni@Sun.COM>
Reply-to: Truong.Q.Nguyen@Sun.COM
Message-id: <42E009C8.7030808@Sun.COM>
MIME-version: 1.0
Content-type: text/plain; charset=us-ascii; format=flowed
Content-transfer-encoding: 7BIT
X-Accept-Language: en-us, en
User-Agent: Mozilla/5.0 (X11; U; SunOS sun4u; en-US; rv:1.7) Gecko/20041221
References: <200507201915.j6KJFmZg033453@sr1-unsh01-03.East.Sun.COM>
 <1121904608.100966.145.camel@thunk>
Status: RO
Content-Length: 2076

Bill,

See comments inline.

Bill Sommerfeld wrote:
> On Wed, 2005-07-20 at 15:15, Brian Utterback wrote:
> 
>>Summary:  This proposal requests a change to the default interlace value for SVM
>>	stripes and RAID5 metadevices and the mirror resync buffer size.  The
>>	new default interlace and resync buffer value of 512KB would result in
>>	15 to 50+ percent increase in throughput for I/O greater 16KB and half
>>	the resynchronization time for mirror initialization and component
>>	failure/recovery.
> 
> 
> On a v40z I set up recently, I noticed substantially *reduced* svm
> mirror initialization performance when I set the resynch buffer size to
> the maximum value, compared with the small default in nevada as of when
> I installed it.
> (the documentation seemed to imply performance could only increase with
> a larger buffer size....)
> 
> I haven't had time to dig into this and the box is now in production.

This sounds strange. Can you get me both SVM config (metastat output) 
and disks related information? In the mean time, I'll see if I can get a 
v40z and try to reproduce this.

> 
> how much measurement of speed vs. resynch buffer size have you done
> across different hardware?

I hadn't done testing with across many different hardware. However, the 
correlation between the reduced resync time and increased resync buffer 
size on my test machine, an x86 with unrecalled hardware specifics, were 
quite consistent.

> maybe this is overengineering but can we somehow make this self-tuning? 
> mirror resynchs typically take at least a few minutes; seems like you
> could do a slow-start-like trick (spend a couple seconds copying at each
> power-of-two-size and then back off if it slows down appreciably?)
> 

I agree and this is what our team has been talking about. The other 
possible enhancement is to utilize the drive buffer to enable larger 
resync regions and IO. However, we just don't have the resource the 
staff such projects now. This fasttrack is intended to be a solution 
that will give us the best bang for the buck.

Thanks,
tony

From sacadmin Mon Jul 25 15:39:05 2005
Received: from eastmail1bur.East.Sun.COM (eastmail1bur.East.Sun.COM [129.148.9.49])
	by sac.sfbay.sun.com (8.12.9+Sun/8.12.9) with ESMTP id j6PMd5Eu019441
	for <PSARC@sac.sfbay.sun.com>; Mon, 25 Jul 2005 15:39:05 -0700 (PDT)
Received: from thunk.east.sun.com (thunk.East.Sun.COM [129.148.174.66])
	by eastmail1bur.East.Sun.COM (8.12.10+Sun/8.12.10/ENSMAIL,v2.2) with ESMTP id j6PMd4Ft011158;
	Mon, 25 Jul 2005 18:39:04 -0400 (EDT)
Received: from 127.0.0.1 (localhost [127.0.0.1])
	by thunk.east.sun.com (8.13.4+Sun/8.13.4) with ESMTP id j6PMd3e4005913;
	Mon, 25 Jul 2005 18:39:03 -0400 (EDT)
Subject: Re: SVM default interlace and resync buffer
	increase	[PSARC/2005/427 Timeout:  07/27/2005]
From: Bill Sommerfeld <sommerfeld@sun.com>
To: Truong.Q.Nguyen@sun.com
Cc: Brian Utterback <blu@sr1-unsh01-03.east.sun.com>, PSARC@sac.sfbay.sun.com,
   Sanjay Nadkarni <Sanjay.Nadkarni@sun.com>
In-Reply-To: <42E009C8.7030808@Sun.COM>
References: <200507201915.j6KJFmZg033453@sr1-unsh01-03.East.Sun.COM>
	 <1121904608.100966.145.camel@thunk>  <42E009C8.7030808@Sun.COM>
Content-Type: text/plain
Message-Id: <1122331143.2863.667.camel@thunk>
Mime-Version: 1.0
X-Mailer: Ximian Evolution 1.4.6.319 
Date: Mon, 25 Jul 2005 18:39:03 -0400
Content-Transfer-Encoding: 7bit
Status: RO
Content-Length: 1066

On Thu, 2005-07-21 at 16:47, Tony Nguyen wrote:
> This sounds strange. Can you get me both SVM config (metastat output) 
> and disks related information? In the mean time, I'll see if I can get a 
> v40z and try to reproduce this.

Tony has gotten back to me with test results.  Turns out the performance
regression I noticed which prompted my comment only happens at a buffer
size which is larger than the proposed new default.

I've asked him to file a man page bug asking for a bit less certainty in
the following section of metasync(1m):

     buffer_size
           Specifies the size (number of 512-byte disk blocks) of
           the  internal  copy  buffer for the mirror resync. The
           size defaults to 128 512-byte disk blocks (64 Kbytes).
           It  can  be no more than 2048 blocks. For best perfor-
           mance (quickest completion of the resync), 2048 blocks
           is the recommended size.

(that paragraph will have to be edited to report the new default
anyway).

I have no problem with the case as proposed.

						- Bill






From sacadmin Fri Jul 29 05:15:34 2005
Received: from eastmail1bur.East.Sun.COM (eastmail1bur.East.Sun.COM [129.148.9.49])
	by sac.sfbay.sun.com (8.12.9+Sun/8.12.9) with ESMTP id j6TCFYEu029778
	for <PSARC@sac.sfbay.sun.com>; Fri, 29 Jul 2005 05:15:34 -0700 (PDT)
Received: from [129.148.226.13] (sr1-unsh01-03.East.Sun.COM [129.148.226.13])
	by eastmail1bur.East.Sun.COM (8.12.10+Sun/8.12.10/ENSMAIL,v2.2) with ESMTP id j6TCFXFt012430;
	Fri, 29 Jul 2005 08:15:33 -0400 (EDT)
Message-ID: <42EA1DE4.5020801@sun.com>
Date: Fri, 29 Jul 2005 08:15:32 -0400
From: Brian Utterback <brian.utterback@sun.com>
User-Agent: Mozilla Thunderbird 1.0.6 (X11/20050715)
X-Accept-Language: en-us, en
MIME-Version: 1.0
To: Brian Utterback <blu@sr1-unsh01-03.east.sun.com>
CC: PSARC@sac.sfbay.sun.com, Truong.Q.Nguyen@sun.com
Subject: Re: SVM default interlace and resync buffer increase [PSARC/2005/427
 Timeout:  07/27/2005]
References: <200507201915.j6KJFmZg033453@sr1-unsh01-03.East.Sun.COM>
In-Reply-To: <200507201915.j6KJFmZg033453@sr1-unsh01-03.East.Sun.COM>
Content-Type: text/plain; charset=ISO-8859-1; format=flowed
Content-Transfer-Encoding: 7bit
Status: RO
Content-Length: 365

The timer has expired on this case. The discussion closed, so I am 
marking it "closed approved fasttrack".

-- 
blu

Remember when SOX compliant meant they were both the same color?
----------------------------------------------------------------------
Brian Utterback - OP/N1 RPE, Sun Microsystems, Inc.
Ph:877-259-7345, Em:brian.utterback-at-ess-you-enn-dot-kom